A money-saving match: Powered Precleaning designed for your custom filtration application Designed for custom filtration applications, our revolutionary Powered Precleaner incorporates patented Gideon® Technology for advanced particle separation, providing precleaned air without adding any airflow resistance. For solutions that integrate Filtration with the Gideon Powered Precleaner, see our RESPA-SD and RESPA-SDX products.
Demo Unit Video: How Gideon Powered Precleaner Works
See how the Gideon Powered Precleaner works.
A rain cap is available for the Gideon Powered Precleaner
Benefits:
Fits on OEM HVAC system
Internal or external installation
Maintains designed cab pressurization over extended operating periods
Increases operator comfort level
Saves money by extending filter life
and lengthening intervals between system maintenance
Specifications:
Mounting: Can be mounted in any plane, horizontally or vertically, as long as the ejection ports are NOT facing straight up (12 o'clock position). Can be installed on a variety of different types of machines.
Dimensions: 3-inch inlet with rain cap: Approximately 9.89”L x 7.875”W x 7.875”H.
Construction: Glass-filled injection molded polypropylene exterior; metal fan blades; 80 watt 12V or 24V DC motor with sealed ball bearings. 3-inch inlet with 5-inch outlet. Optional rain cap available.
Cab Pressurization: Maintains designed cab pressurization over extended operating periods, even when A/C is off, resulting in dramatically increased operator comfort.
Performance:
Will vary according to what filter is used with the system. These results do not include air filter.
Restriction* (in Water column) / Efficiency*:
at 25 CFM • -0.83** inches • 96.4% Efficiency
at 50 CFM • -0.53** inches • 94.3% Efficiency
at 75 CFM • -0.16** inches • 92.4% Efficiency
at 100 CFM • +0.46 inches • 87.4% Efficiency
at 125 CFM • +1.12 inches • 81.6% Efficiency
*Restriction / Efficiency results from Southwest Research Institute, an independent testing lab, using SAE - ISO coarse test dust at 0.056 g/f3 air at 20°C and 101.3 dPa.
** Negative value results mean the powered precleaner is producing positive outlet pressure. Results do not include air filter. Performance will vary depending on what filter/filter housing is used with the system.