A money-saving match: Powered Precleaning
designed for your custom filtration application Designed for custom filtration
applications, our revolutionary Powered Precleaner incorporates
patented Gideon� Technology for advanced particle separation, providing
precleaned air without adding any airflow resistance. For
solutions that integrate Filtration with the Gideon Powered Precleaner,
see our RESPA-SD
and RESPA-SDX
products.
Demo Unit Video: How Gideon
Powered Precleaner Works
See how the Gideon Powered Precleaner
works.
A rain cap is available for the
Gideon Powered Precleaner
Benefits:
Fits on OEM HVAC system
Internal or external installation
Maintains designed cab pressurization over
extended operating periods
Increases operator comfort level
Saves money by extending filter life
and lengthening intervals between system maintenance
Specifications:
Mounting: Can be mounted
in any plane, horizontally or vertically, as long as the ejection ports
are NOT facing straight up (12 o'clock position). Can be installed on a
variety of different types of machines.
Dimensions: 3-inch inlet
with rain cap: Approximately 9.89�L x 7.875�W x 7.875�H.
Construction:
Glass-filled injection molded polypropylene exterior; metal fan blades;
80 watt 12V or 24V DC motor with sealed ball bearings. 3-inch inlet
with 5-inch outlet. Optional rain cap available.
Cab Pressurization:
Maintains designed cab pressurization over extended operating periods,
even when A/C is off, resulting in dramatically increased operator
comfort.
Performance:
Will vary according to what filter is used with the system. These
results do not include air filter.
Restriction* (in Water column) / Efficiency*:
at 25 CFM � -0.83** inches � 96.4% Efficiency
at 50 CFM � -0.53** inches � 94.3% Efficiency
at 75 CFM � -0.16** inches � 92.4% Efficiency
at 100 CFM � +0.46 inches � 87.4% Efficiency
at 125 CFM � +1.12 inches � 81.6% Efficiency
*Restriction / Efficiency results from
Southwest Research Institute, an independent testing lab, using SAE -
ISO coarse test dust at 0.056 g/f3 air at 20�C and 101.3 dPa.
** Negative value results mean the powered precleaner is producing
positive outlet pressure. Results do not include air filter.
Performance will vary depending on what filter/filter housing is used